MPE
MPE Limited
Hammond Road
Knowsley Industrial Park Liverpool
L33 7UL
Contact
T: +44 (0)151 632 9100
E: sales@mpe.co.uk

Two Phase Filter Range

This range of filters was specifically designed to provide optimum high performance filtering on special two line mains supplies where neither line is tied to neutral. They are suitable for voltages up to 250VAC 50/60Hz phase to earth and 440VAC 50/60Hz phase to phase. They feature a combination of feedthrough capacitors with high permeability toroidal current compensating inductors for high performance filtering in a small rectangular case, designed for mounting on a bulkhead. The filters offer 100dB attenuation against electromagnetic noise present on the power lines from a frequency range of 100kHz to 10GHz.

Insertion Loss Performance

Asymmetric attenuation shown as measured in 50Ω system, at all loading conditions, in accordance with CISPR-17.
Performance curve meets 100dB from 100kHz to 10GHz.

Rated Current
(A)
Part NumberDC Resistance
(mΩ)
Earth Leakage
(A)
Length
(mm)
Width
(A)
Height
(mm)
Approx. Weight
(kg)
16DS26367300.9310175908
32DS26368151.45502059516
63DS26369101.455020510520
100DS2637052.264020512022
200DS263712.53.966047513560
400DS263721.23.91250475150110

Rated Voltage

  • 250VAC 56/60Hz
  • 440VAC 50/60Hz phase to phase

Alternative Voltage

  • Also suitable for 480VAC 50/60Hz phase to phase
  • Also suitable for two line d.c. supplies up to 600VDC
  • Alternative surge arrestors may be required.

Rated Current

  • 6A to 200A (each individual line, see table)

Current Overload

  • 10 x maximum rated current for 1 sec.
  • 1.5 x max rated current for 10 minutes.

Discharge time

  • Max. 30 seconds to below 34V (filter incorporates discharge resistors)

Temperature Rise

  • 25°C case rise on full load

Storage Temperature Range

  • -45°C to +85°C Storage
  • -45°C to +50°C Working

MTBF

  • >0.5 million hours (calculated using Mil Hdbk 217F)

Surge Suppression (optional)

  • 270VDC at 140J (8/20μs)
  • All filters can be supplied with an integral metal-oxide varistor, fitted between the input terminal and earth (case).
  • Marine generator supplies
  • Two phases derived from a three phase supply
  • Transformer isolated supplies
  • Supports compliance to MIL-STD-461 & DEF STAN 59-411
  • All MPE installation filters are tested using the test methods defined within the following standards and meet or exceed the relevant performance and/or safety criteria defined within these standards:
    • Mil-F-15733
    • Mil-Std-220C
    • CISPR17:2011/BS EN 55017:2011
    • UL1283
    • LVD 2014/35/EU
    • DEF-STAN 59-411/MIL-STD-461
    • RoHS (2011/65/EU) & LVD (2014/35/EU)
    • UKCA & CE
    DS XXXXX / X / X
    • Filter Part Number
    • Suffix C for standard cable entry
    • For other cable entries, see Installation Details page
    • Add suffix V for transient suppressed filter
    e.g. DS26365CV

    DS XXXXX / X / X

    • Filter Part Number
    • Suffix C for standard cable entry
    • For other cable entries, see Installation Details page
    • Add suffix V for transient suppressed filter

    e.g. DS26365CV