Rated Current | Part Number | DC Resistance
(mΩ) | Earth Leakage*
(A) | Length
(m) | Width
(mm) | Height
(mm) | Approximate Weight
(kg) |
16A | DS25942 | 25 | 1.8 | 550 | 205 | 95 | 16 |
32A | DS25943 | 10 | 1.8 | 550 | 205 | 95 | 18 |
63A | DS25944 | 8 | 1.8 | 640 | 205 | 120 | 22 |
100A | DS25945 | 5 | 1.8 | 660 | 475 | 135 | 60 |
200A | DS26060 | 2 | 4 | 750 | 500 | 160 | 75 |
400A | DS26062 | 0.4 | 4.4 | 1050 | 525 | 185 | 110 |
Rated Curent | Part Number | DC Resistance (mΩ) | Earth Leakage* (A) | Length
(mm) | Width
(mm) | Height
(mm) | Approximate Weight
(kg) |
16A | DS25948 | 25 | 2.2 | 550 | 410 | 95 | 22 |
32A | DS25949 | 10 | 2.2 | 550 | 410 | 95 | 24 |
63A | DS25950 | 8 | 3.15 | 660 | 410 | 135 | 45 |
100A | DS25951 | 5 | 6.3 | 660 | 575 | 150 | 70 |
200A | DS26061 | 2 | 7.8 | 750 | 700 | 170 | 95 |
250A | DS50024 | 1 | 6.3 | 1200 | 700 | 200 | 120 |
400A | DS26063 | 0.4 | 9.45 | 1700 | 700 | 170 | 200 |
Rated Voltage
- 250VAC (SP&N) 50/60Hz
- 440/250VAC (TP&N) 50/60Hz
Alternative Voltage
- Also suitable for 208/120VAC and 480/277VAC
- Alternative surge arrestors may be required.
- TP&N filters are also suitable for three phase supplies without neutral. In such installations, the neutral terminal should be left unconnected.
Rated Current
- 6A to 400A (each individual line, see table)
Current Overload
- 10 x maximum rated current for 1 sec.
- 1.5 x max rated current for 10 minutes.
Discharge time
- 30 seconds to below 30V (filter incorporates discharge resistors)
- If sockets or plugs are used for connection, ensure that no pins or un-insulated parts are accessible by none qualified personnel upon removal.
Temperature Rise
- 25°C case rise on full load
Temperature Range
- -45°C to +85°C Storage
- -45°C to +50°C Working
MTBF
- >0.8 million hours (calculated using Mil Hdbk 217D)
Surge Suppression (optional)
- 275VAC at 215J 10kA 8/20μs
- All filters can be supplied with an integral metal-oxide varistor, fitted
between each input terminal and earth. Add a suffix “V” to end of part code.
Screened Rooms, Server Supplies & EMC Test Chambers
Meets TEMPEST requirement for power filters to NATO SDIP 29/1
Supports compliance to MIL STD 461 & DEF STAN 59 411
All MPE installation filters are tested using the test methods defined within the following standards and meet or exceed the relevant performance and/or safety criteria defined within these standards:
All MPE installation filters are tested using the test methods defined within the following standards and meet or exceed the relevant performance and/or safety criteria defined within these standards:
- Mil-F-15733
- Mil-Std-220C
- CISPR17:2011/BS EN 55017:2011
- UL1283
- LVD 2014/35/EU
- DEF-STAN 59-411/MIL-STD-461
- RoHS (2011/65/EU) & LVD (2014/35/EU)
- UKCA & CE
DS
XXXXX /
X /
X
- Filter Part Number
- Suffix C for standard cable entry
- For other cable entries, see Installation Details page
- Add suffix V for transient suppressed filter
e.g. DS26060CV