DC Class Y4
A range of dc feedthrough filters designed to meet the very stringent safety equirements of EN133200. Capacitors comply with class Y4 rating including the 2500V pulse test. Suitable for all high performance applications requiring high reliability coupled with good high frequency performance such as servers, base stations, and switches.
Standard Performance Range | Typical Insertion Loss (dB) in 50 Ω system with/without load |
Part Number | Current Rating IR (A) @60ºC* | Capacitance Value (nF ±20%) | Inductance (nH) | DC Resistance (mΩ) | 10 KHz | 30 KHz | 100 KHz | 300 KHz | 1 MHz | 10 MHz | 100 MHz | 1 GHz |
DS34230 | 10 | 2 x 10 | 70 | 6 | – | – | 2 | 4 | 10 | 23 | 65 | 100 |
DS34231 | 16 | 2 x 10 | 70 | 4 | – | – | 2 | 4 | 10 | 23 | 65 | 100 |
DS34232 | 32 | 2 x 10 | 70 | 4 | – | – | 2 | 4 | 10 | 23 | 65 | 100 |
DS34233 | 63 | 2 x 100 | 80 | 3 | 2 | 4 | 10 | 18 | 27 | 62 | 95 | 100 |
DS34234 | 100 | 2 x 470 | 90 | 2 | 7 | 14 | 23 | 30 | 32 | 70 | 100 | 100 |
DS34235 | 200 | 2 x 470 | 120 | 1 | 7 | 14 | 23 | 30 | 32 | 70 | 100 | 100 |
Extended Performance Range | Typical Insertion Loss (dB) in 50 Ω system with/without load |
Part Number | Current Rating IR (A) @60ºC* | Capacitance Value (nF ±20%) | Inductance (nH) | DC Resistance (mΩ) | 10 KHz | 30 KHz | 100 KHz | 300 KHz | 1 MHz | 10 MHz | 100 MHz | 1 GHz |
DS34236 | 10 | 2 x 100 | 140 | 8 | 2 | 4 | 10 | 18 | 27 | 67 | 95 | 100 |
DS34237 | 16 | 2 x 100 | 140 | 5 | 2 | 4 | 10 | 18 | 27 | 67 | 95 | 100 |
DS34238 | 32 | 2 x 100 | 140 | 5 | 2 | 4 | 10 | 18 | 27 | 67 | 95 | 100 |
DS34239 | 63 | 2 x 470 | 180 | 3 | 7 | 14 | 23 | 31 | 35 | 75 | 100 | 100 |
DS34240 | 100 | 2 x 1000 | 240 | 2 | 14 | 21 | 30 | 34 | 53 | 75 | 100 | 100 |
DS34241 | 200 | 2 x 4700 | 330 | 2 | 20 | 32 | 40 | 52 | 85 | 100 | 100 | 100 |
Rated Voltage
- 130V dc (also 130V ac 50/60Hz)
Test Voltage
Capacitor Class (EN132400)
Pulse Test (EN132400)
Insulation Resistance (within 1 minute)
- For C 15000MΩ
- For C > 0.33μF, RC < 5000s (MΩ.μF)
Ambient Temperature Range
- -40ºC to +60ºC (+50ºC for 200A units)
Category Temperature Range
Climatic Category
MTBF
- Typically >5 million hours
Insulating materials flammability rating
Mounting Hardware
- 19 A/F fixing nut and crinkle washer
Case
Terminals
Weight
Tightening Torque Terminals
Mounting thread
| Typical Insertion Loss (dB) in 50 Ω system with/without load | | | | | |
Part Number | D ± 0.5 | L ±1 | A ±2 | B ±1 | C | E ±2 | T | Torque on T (N-m) | S | Torque on S (N-m) | Weight (g) |
DS34230 | 20 | 49 | 90 | 12 | 17 | 16 | M12 x 1 | 4 | M3 | 0.5 | 65 |
DS34231 | 20 | 53 | 98 | 12 | 17 | 18 | M12 x 1 | 4 | M4 | 1.2 | 70 |
DS34232 | 20 | 53 | 98 | 12 | 17 | 18 | M12 x 1 | 4 | M4 | 1.2 | 70 |
DS34233 | 25 | 94 | 160 | 14 | 22 | 26 | M16 x 1 | 7 | M6 | 2.5 | 190 |
DS34234 | 32 | 104 | 84 | 16 | 27 | 32 | M20 x 1 | 10 | M8 | 5 | 290 |
DS34235 | 38 | 112 | 209 | 19 | 27 | 40 | M24 x 1 | 14 | M10 | 8 | 460 |
DS34236 | 20 | 89 | 130 | 12 | 17 | 16 | M12 x 1 | 4 | M3 | 0.5 | 120 |
DS34237 | 20 | 94 | 139 | 12 | 17 | 18 | M12 x 1 | 4 | M4 | 1.2 | 130 |
DS34238 | 20 | 94 | 139 | 12 | 17 | 18 | M12 x 1 | 4 | M4 | 1.2 | 130 |
DS34239 | 32 | 105 | 173 | 16 | 27 | 26 | M20x 1 | 10 | M6 | 2.5 | 280 |
DS34240 | 38 | 145 | 228 | 19 | 27 | 32 | M24 x 1 | 14 | M8 | 5 | 600 |
DS34241 | 54 | 182 | 279 | 19 | 40 | 40 | M27 x 1.5 | 16 | M10 | 8 | 1500 |