Clean Power Filter Range

The Clean Power range of filters for electrical connection to SP&N and TP&N mains distribution systems, are designed for use in industrial applications or EMC installations where very high frequency performance is not required. The filters are housed in a rugged stainless steel rectangular case, designed for mounting on a bulkhead.

Insertion Loss Performance

Asymmetric attenuation shown as measured in 50Ω system, at all loading conditions, in accordance with CISPR-17.
Performance curve meets 100dB from 100kHz to 1GHz.

CleanPower Filter Range

Rated Current
(A)
Part NumberDC Resistance
(mΩ)
Earth Leakage
(A)
Length
(mm)
Width
(A)
Height
(mm)
Approx. Weight
(kg)
16ADS41016200.2250110553
32ADS4103260.3350120655
63ADS4106320.4400140808
100ADS411000.80.65002009518
160ADS411600.50.860021011025
Rated Current
(A)
Part NumberDC Resistance
(mΩ)
Earth Leakage
(A)
Length
(mm)
Width
(A)
Height
(mm)
Approx. Weight
(kg)
16ADS43016120.3250110554
32ADS4303250.5350120658
63ADS430631.50.74001408012
100ADS431000.515002009520
160ADS431600.21.360021011030

Rated Voltage SP&N

  • 250VAC 50/60Hz

Rated Voltage TP&N

  • 440/250VAC 50/60Hz

Alternative Voltage SP&N

  • Also suitable for 520/300VAC 50/60Hz two phase
  • Also suitable for 2 line d.c. supplies up to 400VDC
  • Alternative surge arrestors may be required.

Alternative Voltage TP&N

  • Also suitable for 480/277VAC 50/60Hz
  • Also suitable for 520/300VAC 50/60Hz
  • Alternative surge arrestors may be required.

Rated Current

  • 6A to 160A (each individual line, see table)

Current Overload

  • 10 x maximum rated current for 1 sec.
  • 1.5 x max rated current for 15 minutes.

Discharge time

  • Max. 30 seconds to below 34V (filter incorporates discharge resistors)

Temperature Rise

  • 20°C case rise on full load

Storage Temperature Range

  • -45°C to +85°C Storage
  • -45°C to +50°C Working

MTBF

  • >0.2 million hours (calculated using Mil Hdbk 217F)

Surge Suppression (optional)

  • 320VAC at 255J (8/20μs)
  • All filters can be supplied with an integral metal-oxide varistor, fitted between the input terminal and earth (case).
  • Industrial power and equipment supplies
  • Screened rooms, enclosures, cabinets and server supplies
  • Supports compliance to MIL-STD-461 & DEF STAN 59-411
  • All MPE installation filters are tested using the test methods defined within the following standards and meet or exceed the relevant performance and/or safety criteria defined within these standards:
    • Mil-F-15733
    • Mil-Std-220C
    • CISPR17:2011/BS EN 55017:2011
    • UL1283
    • LVD 2014/35/EU
    • DEF-STAN 59-411/MIL-STD-461
    • RoHS (2011/65/EU) & LVD (2014/35/EU)
    • UKCA & CE
    DS XXXXX / X / X
    • Filter Part Number
    • Suffix C for standard cable entry
    • For other cable entries, see Installation Details page
    • Add suffix V for transient suppressed filter